Type: | Self-Starting Diesel Generator |
---|---|
Installation Method: | Portable |
Stroke: | Four Stroke |
Cooling Method: | Air Cooled |
Output Type: | AC Single Phase |
Speed: | Speed |
Customization: |
---|
Suppliers with verified business licenses
1.CE;CCC;ISO9001
2.global guarantee
3.good price and high quality
4.fastest delivery time
5kva DIESEL GENERATOR SET
Genset Model |
GFDF-10 |
||
Prime power(KW/KVA) |
4.8kw/5kva |
Standby Power(KW/KVA) |
6kw/6.5kva |
Voltage: |
400/230V |
Rated Speed (rpm) |
1500rpm |
Frequency (Hz) |
50HZ |
Rated Current (A) |
9 |
Connection: |
3 phase 4 wire |
Power Factor: |
0.8 |
Engine Model: |
3TNG70-GGE |
Alternator Model: |
STF164A |
Weight (kgs)-Open |
1024 |
Weight (kgs)-Silent |
1280 |
Dimensions (mm)-Open |
1900*800*1000 |
Dimensions (mm)-Silent |
2050*950*1150 |
Kanpor engine diesel set 5kva,Engine data:
Manufacturer/Model: 3TNG70-GGE
Aspiration: Turbocharge
Cylinder numbers 3cylinders
Displacement: 3.12L
Bore x Stroke 105*120(mm
Compression Ratio: 18:1
Max. Power: 5kw
Governing System: Mechanical/Electronic
100% Load (Standby): 208g/Kw.h
Cooling way: air-cooled
Quality Assurance
Factory Inspection, the test items before delivery are mainly as follows:
1. Each genset shall be put into commission more than 4 hours totally.
They are tested on idle load, fully load and 10% overload
2. The noise level is tested
3. All of the meters on the control panel shall be tested
4. The appearance of the genset and all of the label and nameplate shall be checked
Warranty
12 months or 1000 running hours from shipment date. If the quality problem arise during the warranty period,and verified the problem is caused by our genset-body instead of external or natural reasons. (Refer to all kinds of natural disaster, shipping, loading, unloading, wrong-operation, etc), we will supply the relevant spare parts free of charge for maintenance; after the warranty period, we can supply the required spare parts for you under cost prices
Suppliers with verified business licenses