1. GENERATOR DATA
Voltage Available:
50Hz: 380-400-415V/220-230-240V;
60Hz: 220-380-416-440-480V/110-208-220-240V
Any special voltage is also available as client's request
Prime Power:
Comply with GB/T2820-97(eqv.ISO8528).
Genset can run unlimitedly under certain power range.
One hour 10% over load in every 12 running hours is allowed;
Standby Power:
standby power is the limit value of maximum output for emergency use.
It is off-oil power,overloading is prohibited
2. MAIN SPECIFICATION
Genset Model | KPYM25 | KPYM40 | KPYM50 | KPYM55 | KPYM66 | |
Rated Power | KW/KVA | 18/22.5 | 30/37.5 | 36/45 | 40/50 | 48/60 |
Standby Power | KW/KVA | 20/25 | 32/40 | 40/50 | 44/55 | 52.8/66 |
Rated Voltage | V | 220V/127V 380V/220V 400V/230V 415V/240V 480V/277V 600V/346V | ||||
Speed | RPM | 1500/1800 | ||||
Rated frequency | Hz | 50/60 | ||||
Engine Model | 4TNV84T-GGE | 4TNV98-GGE | 4TNV98T-GGE | 4TNV106-GGE | 4TNV106T-GGE | |
Engine Power | KW | 21 | 34.1 | 41.4 | 49.4 | 56 |
Air intake way | Turbo | Natural | Turbo | Natural | Turbo | |
Governor | Electronic | Electronic | Electronic | Electronic | Electronic | |
Cylinder | QTY | 4 | 4 | 4 | 4 | 4 |
Bore*Stroke | mm*mm | 84×90 | 98×110 | 98×110 | 106×125 | 106×125 |
Displacement | L | 1.995 | 3.319 | 3.319 | 4.412 | 4.412 |
Fuel Consumption | g/kw.h | 245 | 231 | 222 | 237 | 220 |
Compression Ratio | 18.9:1 | 18.5:1 | 18.1:1 | 18:1 | 18:1 | |
Alternator Model | STF-184E | STF-184H | STF-224C | STF-224D | STF-224E | |
Voltage Regulation | AVR | |||||
Excitation Method | Brushless | |||||
Open Type Size | mm | 1580x810x990 | 1580x810x990 | 1880x810x1165 | 1880x810x1165 | 1880x810x1165 |
Open Type Weight | kg | 780 | 800 | 830 | 850 | 890 |
Soundproof Size | mm | 1950x900x1100 | 1950x900x1100 | 2200x1050x1200 | 2200x1050x1200 | 2200x1050x1200 |
Soundproof Weight | kg | 1060 | 1110 | 1140 | 1160 | 1210 |
(1).Full control panel with power indicator light and oil light.
(2).Emergency shutdown for low oil pressure and high water temperature.
(3).Large fuel tank ensure continuous running.
(4).Low noise & vibration.
(5).Compact structure.
(6).Reliable performance.
(7).Easy for installation and maintenance.
(8).50Hz and 60Hz both are available for choice