Customization: | Available |
---|---|
Type: | Self-Starting Diesel Generator |
Installation Method: | Fixed |
Still deciding? Get samples of US$ 5700/Piece
Request Sample
|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
50Hz 32kw 40kVA Silent weatherproof Cummins 4BT3.9G2/36 Diesel Genset
1.★ GENERATOR DATA/SPECIFICATION
Voltage Available:
50Hz: 380V/220V 400V/230V 415V/240V 480V/277V
60Hz: 220V/127V 230V/132V 220V/440V 240V/480V
Any special voltage is also available as client's request
Prime Power:
Comply with GB/T2820-97(eqv.ISO8528).
Genset can run unlimitedly under certain power range.
One hour 10% over load in every 12 running hours is allowed;
Standby Power:
standby power is the limit value of maximum output for emergency use.
It is off-oil power,overloading is prohibited
★ PRODUCT FEATURES
(1).Full control panel with power indicator light and oil light.
(2).Emergency shutdown for low oil pressure and high water temperature.
(3).Large fuel tank ensure continuous running.
(4).Low noise & vibration.
(5).Compact structure.
(6).Reliable performance.
(7).Easy for installation and maintenance.
(8).50Hz and 60Hz both are available for choice
Safety
2.★MAIN SPECIFICATION
40KVA cummins diesel genset main specifications:
The main parameters of KPC45 | |
Manufacturer: | KANPOR ELECTRICAL MACHINERY CO.,LTD. |
Model: | KPC45 |
Prime Power: | 32KW / 40KVA |
Standby Power: | 36KW / 45KVA |
Frequency: | 50HZ |
Voltage: | 400/230V |
Phase: | 3 Phase |
P.F(COS): | 0.8 |
Fuel: | Diesel |
Rated Current: | 43.2A |
Start Method: | 24V DC Start Battery |
Accessory: | Battery, wire, exhaust pipe, muffler, damper, breaker |
Altitude: | ≤1000m |
Engine Specifications | |
Brand and Model: | Original Cummins 4BT3.9-G2/36kw |
Aspiration: | Naturally |
Cylinder Arrangement: | 3 in line |
Displacement: | 3.3L |
Bore and Stroke: | 105×127 mm |
Compression Ratio: | 23.3:1 |
Rated RPM: | 1500rpm |
Maximum Output Power: | 36KW |
Governor Type: | Mechanical |
100% Load Fuel Consumption: | 211 g/Kw.h |
Total Lubrication Capacity: | 7.9L |
Total Coolant Capacity: | 10.2L |
Cooling System: | Forced water cooling cycle |
Alternator Specifications | |
Manufacturer: | Stamford |
Model: | PI144J |
Rated Capacity: | 40KVA |
Winding: | 100% Copper Wire |
Frequency: | 50HZ |
Speed: | 1500 RPM |
Connecting Type: | 3 Phase and 4 Wires, "Y" type connecting |
Power Factor: | 0.8 |
Protection Grade: | IP23 |
Alternator Warranty: | 2 Year No Time Limited |
Exciter Type: | Brushless, self-exciting, with AVR |
Insulation Class, Temperature Rise: | H/H |
Voltage Regulation: | ≥±5% |
Control System Specifications | |
Main Features: | a) Instruments:Analogue Volmeter,Hours Run Meter.Water pressure Meter. b) Controls:Emergency Stop Pushbutton,Volmeter Phase Selector Switch. |
Manufacturer: | DEEP SEA ELECTRONICS PLC (UK) |
Model: | DSE7310 |
Type: | Manual Operation |
Operation: | Via a three position key switch ;with STOP(O), RUN(I) and START(II). |
Alarm Protect: | Low Oil Pressure, High Engine Temperature, Auxiliary Shutdown, Charge Failure |
Δ Automatic mains failure | Δ Mains simulation |
Δ Engine control,Generator protection | Δ Block heater control |
Δ Built in alarms and warnings | Δ Field adjustable parameters |
Δ Remote Start operation available | Δ Free MS-Windows Remote monitoring |
Δ Daily / weekly / monthly exerciser | Δ LED displays |
Δ Weekly operation schedule programs | Δ Configurable analogue inputs |
Δ Fuel pump control | Δ I/O expansion capability |
Δ ECU control and monitoring via J1940 CANBUS | D+ preexcitation terminal |
AUTOMATIC MAINS FAILURE | 7 binary inputs and outputs |
Size and Weight | |
Open Type Overall Size: | 1800mm*700mm*1340mm |
Weight: | 930 KG |
Soundproof Type Overall Size: | 2100mm*1000mm*1200mm |
Weight: | 1300 KG |