Customization: | Available |
---|---|
Type: | Self-Starting Diesel Generator |
Installation Method: | Fixed |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
1. GENERATOR DATA
Voltage Available:
50Hz: 380-400-415V/220-230-240V;
60Hz: 220-380-416-440-480V/110-208-220-240V
Any special voltage is also available as client's request
Prime Power:
Comply with GB/T2820-97(eqv.ISO8528).
Genset can run unlimitedly under certain power range.
One hour 10% over load in every 12 running hours is allowed;
Standby Power:
standby power is the limit value of maximum output for emergency use.
It is off-oil power,overloading is prohibited
2. MAIN SPECIFICATION
Powered by Cummins engine
RATED POWER | 40KW (50KVA) | ||||||
STANDBY POWER | 44KW (55KVA) | ||||||
RATED FREQUENCY | 50HZ / 1500RPM | ||||||
POWER FACTOR | 0.8 (HYSTERESIS) | ||||||
OUTPUT VOLTAGE | 230V / 400V | ||||||
OUTPUT CURRENT | 72A / 96A | ||||||
PHASE | THREE PHASE, 4 WIRES |
(1). The Rated power is that continue working power can be volatile, without time limited. | |||||||
(2). The Standby power refers to the instantaneous maximum running power of the generator set, | |||||||
engine without overload capacity under standby power, no overload! | |||||||
(3). 60HZ and corresponding voltage for optional. Engine speed under 60hz is 1800rpm. | |||||||
The power of generator set will be about 10% more than that under 50hz. |
ENGINE TYPE | FOUR STROKES, IN LINE, 4 CYLINDERS, DIESEL ENGINE | ||||||
DISPLACEMENT: (L) | 3.9 | ||||||
AIR INLET | INTER-COOLED TURBOCHARGED | ||||||
BORE(MM)/ STROKE(MM) | 102/120 | ||||||
COMPRESSION RATIO | 16.5:1 | ||||||
ENGINE SPEED | 1500RPM | ||||||
IDLING SPEED | 950-1050 | ||||||
RATED POWER | 50KW | ||||||
STANDBY POWER | 55KW | ||||||
PISTON SPEED | 7.2M/S | ||||||
FRICTION POWER | 8.2KW | ||||||
SPEED GOVERNOR | ELECTRONIC GOVERNOR | ||||||
FORM OF FUEL SYSTEM | NYC A INLINE PUMP | ||||||
WEIGHT OF THE ENGINE | 350KGS | ||||||
INLET FLOW | 48 Litre/Section | ||||||
EXHAUST TEMPERATURE | 460ºC | ||||||
EXHAUST FLOW | 130 Litre/Section | ||||||
SMOKE EXHAUST RATE | 10(m3/min) | ||||||
AMOUNT OF GAS | 4.3 (m3/min) | ||||||
EXHAUST AIR RATE | 136(m3/min) | ||||||
FUEL CONSUMPTION | 216 (g/kw.h) or 13.1 (L/h) | ||||||
FUEL GRADE | 0# LIGHT DIESEL | ||||||
OIL CONSUMPTION | ≤1 (g/kw.h) | ||||||
ALLOWED HIGHEST OIL TEMPERATURE | 121ºC (250 ºF) | ||||||
GRADE OF LUBRICATING OIL | 15W/40 | ||||||
LUBRICATING OIL CAPACITY | 11L | ||||||
COOLING LIQUID CAPACITY | 7.9L |
Coupled with Stamford alternator (3 years' warranty)
Alternator Model |
UCI274C |
Prime power |
80KW |
Frequency/speed |
50HZ/1500rpm |
Exciter type |
Single bearing, Brushless, Self-excited |
Power factor |
0.8 |
Voltage adjust range |
≥5% |
Voltage regulation NL-FL |
≤±1% |
Insulation Grade |
H |
Protection Grade |
IP23 |
Phase |
Three phases |
100KVA diesel generator, the control panel we can use ComAp IL9, ComAp MRS10, ComAp AMF20 or AMF25, SmartGen HGM6110N or HGM6120N, DeepSea DSE6020 and DSE7320
Model |
MRS10/DSE6020/HGM6110N... |
The control module gives digital readouts of: Generator voltage; Output frequency; Engine speed; Battery voltage; Engine hours run. The control module has indicators for failure information: Overspeed/underspeed, Emergency stop Low oil pressure; High water temperature Failure to start Battery charger failure Automatic shutdown occurs under: Low engine oil pressure; High engine water temperature; Overspeed/underspeed; Failure to start after three attempts. |
Standard Accessories |
Open type |
Silent type |
Sound-proof & Weather-proof Canopy |
N/A |
√ |
Daily base fuel tank. 8 hours capacity |
N/A |
√ |
Single-bearing generator again drops |
√ |
√ |
Intelligent LED display control panel |
√ |
√ |
Speed governor |
√ |
√ |
Electric start and 24v charger |
√ |
√ |
Standard air filter, oil filter, fuel filter |
√ |
√ |
Cooling water tank |
√ |
√ |
High-efficient silencer. |
√ |
√ |
Exhaust elbow |
√ |
√ |
Storage battery |
√ |
√ |
Steel base-frame against vibration |
√ |
√ |
Soft pipe for fuel and handle for lube going-out |
√ |
√ |
Operation& Maintenance manual. |
√ |
√ |
(1).Full control panel with power indicator light and oil light.
(2).Emergency shutdown for low oil pressure and high water temperature.
(3).Large fuel tank ensure continuous running.
(4).Low noise & vibration.
(5).Compact structure.
(6).Reliable performance.
(7).Easy for installation and maintenance.
(8).50Hz and 60Hz both are available for choice