KPF150 Good Quality 50Hz Prime output 112kw 140kVA FAW (CA6DF2-17D) Diesel Genset
Model: | KPF150 |
Prime Power (kw/kva ) | 112/140 |
Standby Power(kw /kva ) | 120/150 |
Rated Voltage | 400/230V (Adjustable) |
Frequency | 50Hz |
Radiator | 50°C suitable for tropical weather |
Power Factor | 0.8(lagging) |
Fuel: | Diesel |
Start Method: | 24V DC Start Battery |
Accessory: | Battery, wire, exhaust pipe, muffler, damper, breaker |
Altitude: | ≤1000m |
Base Feul Tank Capacity | Enough for Genset 8-10 Hours Continuous Running |
Engine Specifications | |
Engine Manufacturer | Faw Jiefang Automotive Co., Ltd Wuxi Diesel Engine Works |
Engine Brand | Fawde |
Engine Model | CA6DF2-17D |
No.of Cylinder | 6 Cylinder in line |
Bore | 110mm |
Stroke | 125mm |
Displacement | 7.13L |
Compress Air Flow | 9 m3/min |
Exhaust Gas Flow | 25 m3/min |
Exhaust Gas Temperature | 470 ºC |
Lubrication Oil Capacity | 23 L |
Cooling Water Capacity | N.A.L |
Starting Voltage | 24V |
Engine Max.Output Power | 138KW |
Alternator Specifications | |
Alternator brand | KANPOR |
Model | STF274E-112KW |
Power Factor(COS Phi) | 0.8 |
Excite Type | Brushless SHUNT |
Connecting Type | 3 Phase & 4 Wires |
Insulation Degree | H |
Enclosure Degree | IP23 |
AVR voltage regulation rate | ≤±0.5% |
Voltage Regulation, Steady State | ≤±0.5% |
Transient State Voltage | ≤-15%~+20% |
Exciter Type: | Brushless, self-exciting, with AVR |
Insulation Class, Temperature Rise: | H/H |
Voltage Regulation: | ≥±5% |
Control System Specifications | |
Main Features: | a) Instruments:Analogue Volmeter,Hours Run Meter.Water pressure Meter. b) Controls:Emergency Stop Pushbutton,Volmeter Phase Selector Switch. |
Manufacturer: | DEEP SEA ELECTRONICS PLC (UK) |
Model: | DSE6010 |
Type: | Manual Operation |
Operation: | Via a three position key switch ;with STOP(O), RUN(I) and START(II). |
Alarm Protect: | Low Oil Pressure, High Engine Temperature, Auxiliary Shutdown, Charge Failure |
Δ Automatic mains failure | Δ Mains simulation |
Δ Engine control,Generator protection | Δ Block heater control |
Δ Built in alarms and warnings | Δ Field adjustable parameters |
Δ Remote Start operation available | Δ Free MS-Windows Remote monitoring |
Δ Daily / weekly / monthly exerciser | Δ LED displays |
Δ Weekly operation schedule programs | Δ Configurable analogue inputs |
Δ Fuel pump control | Δ I/O expansion capability |
Δ ECU control and monitoring via J1940 CANBUS | D+ preexcitation terminal |
AUTOMATIC MAINS FAILURE | 7 binary inputs and outputs |
Size and Weight | |
Open Type Overall Size: | 2500mm*900mm*1500mm |
Weight: | 1600 KG |
Soundproof Type Overall Size: | 2900mm*1100mm*1600mm |
Weight: | 2480 KG |
1.★ GENERATOR DATA/SPECIFICATION
FAW Jiefang Automotive Company Ltd. Wuxi Diesel Engine Works (FAWDE), Short for FAW-Xichai. It is a professional diesel engine provider in China, doing business since 1943,FAW (The leading company of china auto industry). Diesel engines are very reliable, and easily adapt to damp environments, for they have no high-tension electrical ignition system to attend to. They also have more solid parts and better lubrication properties, so they have a longer service life.
Voltage Available:
50Hz: 380V/220V 400V/230V 415V/240V 480V/277V
60Hz: 220V/127V 230V/132V 220V/440V 240V/480V
Any special voltage is also available as client's request
Prime Power:
Comply with GB/T2820-97(eqv.ISO8528).
Genset can run unlimitedly under certain power range.
One hour 10% over load in every 12 running hours is allowed;
Standby Power:
standby power is the limit value of maximum output for emergency use.
It is off-oil power,overloading is prohibited
★ PRODUCT FEATURES
(1).Full control panel with power indicator light and oil light.
(2).Emergency shutdown for low oil pressure and high water temperature.
(3).Large fuel tank ensure continuous running.
(4).Low noise & vibration.
(5).Compact structure.
(6).Reliable performance.
(7).Easy for installation and maintenance.
(8).50Hz and 60Hz both are available for choice
2.★MAIN SPECIFICATION
50HZ 1500RPM | 60HZ 1800RPM | ||||||||
PRIME OUTPUT | DIESEL ENGINE MODEL FAW |
ALTERNATOR MODEL Kanpor |
PRIME OUTPUT | DIESEL ENGINE MODEL FAW |
ALTERNATOR MODEL Kanpor |
||||
KW | KVA | KW | KVA | ||||||
12.8 | 16 | 4DW81-23/19 | STF164D-12.8KW | 16 | 20 | 4DW81-28D/22 | BC164D/16 | ||
16 | 20 | 4DW81-23/19 | STF184E-18KW | 22 | 27.5 | 4DW91-38D/31 | BC184E/22 | ||
18 | 22.5 | 4DW91-29/23 | STF184E-18KW | 24 | 30 | 4DW91-38D/31 | BC184F/26 | ||
22 | 27.5 | 4DW92-35D/29 | STF184F-22KW | 26 | 27.5 | 4DW92-42D/34 | BC184F/26 | ||
24 | 30 | 4DW93-42D/34 | STF184G-25KW | 30 | 38 | 4DW93-50D/41 | BC184G/30 | ||
30 | 37.5 | 4DX21-45D/36 | STF184H-30KW | 34 | 42.5 | 4DW93-50D/41 | BC184H/34 | ||
34 | 42.5 | 4DX22-50D/41 | STF224C-34KW | 34 | 42.5 | 4DX21-53D/43 | BC184H/34 | ||
40 | 50 | 4DX23-65D/53 | STF224D-40KW | 40 | 50 | 4DX22-60D/50 | UC224C/44 | ||
48 | 60 | 4110/125Z-09D/72 | STF224E-48KW | 40 | 50 | 4DX23-82D/66 | UC224D/50 | ||
58 | 72.5 | 4110/125Z-09D/72 | STF224F-58KW | 48 | 60 | 4110/125Z-11D/88 | UC224E/56 | ||
68 | 85 | CA4DF2-12D/92 | STF224G-68KW | 58 | 72.5 | 4110/125Z-11D/88 | UC224F/68 | ||
80 | 100 | CA4DF2-12D/92 | STF274C-80KW | 68 | 85 | CA4DF2-14D/110 | UC224G/80 | ||
80 | 100 | CA6DF2D-14D/105 | STF274C-80KW | 80 | 100 | CA4DF2-14D/110 | UC274C/96 | ||
96 | 120 | CA6DF2-17D/138 | STF274D-96KW | 80 | 100 | CA6DF2D-16D/128 | UC274C/96 | ||
112 | 140 | CA6DF2-17D/138 | STF274E-112KW | 96 | 120 | CA6DF2-18D/145 | UC274D/106 | ||
|
160 | CA6DF2-19D/154 | STF274F-128KW | 112 | 140 | CA6DF2-18D/145 | UC274E/128 | ||
|
180 | CA6DL1-24D/194 | STF274G-145KW |
|
160 | CA6DF2-21D/170 | UC274F/144 | ||
160 | 200 | CA6DL1-24D/194 | STF274H-160KW | 144 | 180 | CA6DL1-27D/215 | UC274G/160 | ||
|
225 | CA6DL1-24D/194 | STF274J-180KW | 160 | 200 | CA6DL1-27D/215 | UC274H/190 | ||
180 | 225 | CA6DL2-27D/226 | STF274J-180KW | 180 | 225 | CA6DL1-27D/215 | UC274J/200 | ||
200 | 250 | CA6DL2-27D/226 | STF274K-200KW | 180 | 225 | CA6DL2-32D/259 | UC274J/200 | ||
220 | 275 | CA6DL2-30D/251 | STF314C-200KW | 200 | 250 | CA6DL2-32D/259 | UC274K/240 | ||
236 | 295 | CA6DM2J-39D/316 | STF314D-236KW | 304 | 380 | CA6DM2J-42D/336 | HC314D/280 | ||
260 | 325 | CA6DM2J-39D/316 | STF314ES-260KW | 320 | 400 | CA6DN1J-46D/369 | HC314E/312 | ||
304 | 380 | CA6DM2J-41D/330 | STF314FS-304KW | ||||||
320 | 400 | CA6DN1J-45D/365 | STF314F-320KW |