Voltage Available:50Hz: 380-400-415V/220-230-240V;
60Hz: 220-380-416-440-480V/110-208-220-240V
Any special voltage is also available as client's request
Prime Power:
Comply with GB/T2820-97(eqv.ISO8528).
Genset can run unlimitedly under certain power range.
One hour 10% over load in every 12 running hours is allowed;
Standby Power:
standby power is the limit value of maximum output for emergency use.
It is off-oil power,overloading is prohibited
★ MAIN TECHNICAL DATA/SPECIFICATIONMODEL | KP1800 | KP2500 | KP2900 | KP3500 | KP5500 | KP6500 | KP7500 | |||||||||
Generator | Rated AC output (kw) | 1.4 | 1.7 | 2 | 2.2 | 2.5 | 2.7 | 3 | 3.2 | 4.5 | 5 | 5 | 5.5 | 6 | 6.5 | |
Max AC output (kw) | 1.6 | 1.9 | 2.2 | 2.4 | 2.7 | 2.9 | 3.2 | 3.4 | 5 | 5.5 | 5.5 | 6 | 6.5 | 7 | ||
Rated AC Voltage (V) | 110/120/220/230/240/380/400 | 110/120/220/230/240/380/400 | 110/120/220/230/240/380/400 | 110/120/220/230/240/380/400 | 110/120/220/230/240/380/400 | 110/120/220/230/240/380/400 | 110/120/220/230/240/380/400 | |||||||||
Frequency (Hz) | 50 | 60 | 50 | 60 | 50 | 60 | 50 | 60 | 50 | 60 | 50 | 60 | 50 | 60 | ||
Power factor | 1 | 1 | 1 | 1 | 1 | 1 | 1 | |||||||||
Engine | Model | KP168F-1 | KP168F-2 | KP168F-2 | KP170F | KP188F | KP188F | KP190F | ||||||||
Type | 4-stroke,single cylinder, air-cooled |
4-stroke,single cylinder, air-cooled |
4-stroke,single cylinder, air-cooled |
4-stroke,single cylinder, air-cooled |
4-stroke,single cylinder, air-cooled |
4-stroke,single cylinder, air-cooled |
4-stroke,single cylinder, air-cooled |
|||||||||
Max. Output(HP/rpm) | 5.5/3600 | 6.5/3600 | 6.5/3600 | 7.0/3600 | 13.0/3600 | 13.0/3600 | 15.0/3600 | |||||||||
Ignition system | Non-Contact Transistorized Ignition(T.C.I) | Non-Contact Transistorized Ignition(T.C.I) | Non-Contact Transistorized Ignition(T.C.I) | Non-Contact Transistorized Ignition(T.C.I) | Non-Contact Transistorized Ignition(T.C.I) | Non-Contact Transistorized Ignition(T.C.I) | Non-Contact Transistorized Ignition(T.C.I) | |||||||||
Starting system | Recoil Starting | Recoil Starting | Recoil Starting | Recoil Starting | Recoil Starting | Recoil Starting | Recoil Starting | |||||||||
Fuel | Unleaded Gasoline | Unleaded Gasoline | Unleaded Gasoline | Unleaded Gasoline | Unleaded Gasoline | Unleaded Gasoline | Unleaded Gasoline | |||||||||
Fuel tank capacity(L) | 15 | 15 | 15 | 15 | 25 | 25 | 25 | |||||||||
Continuous work(h) | 12 | 11 | 10.5 | 10 | 9 | 8.5 | 8 | |||||||||
Displacement(cc) | 160 | 200 | 200 | 210 | 390 | 390 | 420 | |||||||||
Packing | Dimension LxWxH(mm) | 605x445x450 | 605x445x450 | 605x445x450 | 605x445x450 | 690x525x552 | 690x525x552 | 690x525x552 | ||||||||
N.G(kg) | 38 | 41 | 44 | 46 | 76 | 81 | 95 | |||||||||
20'FCL(pcs) | 235 | 235 | 235 | 235 | 144 | 144 | 144 |
★ PRODUCT FEATURES
(1).Full control panel with power indicator light and oil light.
(2).Emergency shutdown for low oil pressure and high water temperature.
(3).Large fuel tank ensure continuous running.
(4).Low noise & vibration.
(5).Compact structure.
(6).Reliable performance.
(7).Easy for installation and maintenance.
(8).50Hz and 60Hz both are available for choice
FAQ
1.What's your power range of Generators?
Answer: We can offer the range from 1kva~1250kva.
2.What's your delivery time?
Answer: Generally,we can delivery in 15-30 days after we get the deposit.
3.What's your payment?
Answer: We accept T/T ,and 30% as the deposit,the balance payment should be paid before delivery the goods.
4.What's your warranty?
One year or 1000hours (accord to whichever reach first) from Ex-Factory date
5.What's your MOQ?
Answer:We accept small power generator MOQ is 10 or 20 sets .Other accept 1 set.