Customization: | Available |
---|---|
After-sales Service: | Factory Warranted |
Warranty: | 1 Year or 1000 Running Hours |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
1. GENERATOR DATA
Voltage Available:
50Hz: 380-400-415V/220-230-240V;
60Hz: 220-380-416-440-480V/110-208-220-240V
Any special voltage is also available as client's request
Prime Power:
Comply with GB/T2820-97(eqv.ISO8528).
Genset can run unlimitedly under certain power range.
One hour 10% over load in every 12 running hours is allowed;
Standby Power:
standby power is the limit value of maximum output for emergency use.
It is off-oil power,overloading is prohibited
2. MAIN SPECIFICATION
Model | Prime output(kw/kva) |
Standby output(kw/kva) | Engine model | Alternator model |
KPYD33 | 24/30 | 27/33 | YD490D | STF-184E |
Genset Data | Size & Weight (Rear-cab type) | 1700*700*900mm (500kgs) | ||
Frequency | 60Hz | |||
Standard Features | Radiator 50OC max, fans are driven by belt, with safety guard/Ripple flex exhaust pipe, exhaust siphone, flange, muffler | |||
Voltage | 460V | |||
Phase & Wires | Three phase | |||
Power Factor | COSΦ=0.8 (lagging) | |||
Battery | 12V | |||
Fuel Tank | 60L Fuel Tank included | |||
Breaker | CHINT | |||
Engine Data |
Brand & Model | Yangdong YD490D | ||
Cycle | 4 stroke | |||
Engine Power (kwm) | 27KW | |||
Air Intake Way | Natural | |||
Governor | Mechanical | |||
Cylinder | 4 | |||
Bore*Stroke (mm) | 90*105 | |||
Displacement (L) | 2.672 | |||
Fuel Consumption | 223g/kw.h against prime power | |||
Compression Ratio | 18:1 | |||
Combustion System | Direct injection | |||
Speed | 1800RPM | |||
Cooling Way | Water cooled | |||
Alternator Data |
Brand & Model | Kanpor STF-184E | ||
Alternator Power | 24KW | |||
Frequency & Speed | 60Hz, 1800RPM | |||
Phase & Voltage | Three phases 460V | |||
System | Brushless AC Synchronous, Single bearing | |||
Insulation & Protection | H, IP23 | |||
Voltage Regulator | Standard AVR | |||
Control System |
Brand & Model | Smartgen HGM420N | ||
Two language interface: Chinese/English | ||||
Start or Stop Generator set manually / automatically; Open controller output can be defined as Pre-heat/Idle output. | ||||
High Coolant temperature protection; Low Oil pressure protection. Over speed protection | ||||
Over load protection; Generator over/under frequency protection: Generator over/under/unbalance voltage protection |
3. PRODUCT FEATURES
(1).Full control panel with power indicator light and oil light.
(2).Emergency shutdown for low oil pressure and high water temperature.
(3).Large fuel tank ensure continuous running.
(4).Low noise & vibration.
(5).Compact structure.
(6).Reliable performance.
(7).Easy for installation and maintenance.
(8).50Hz and 60Hz both are available for choice